ASTM D323 FDR-0202 Saturated vapor pressure tester (Reid method)

ASTM D323 FDR-0202 Saturated vapor pressure tester (Reid method)

Saturation vapor pressure of petroleum products in accordance with applicable standards ADTM D323,GB / T8017-2012 «Determination of vapor pressure of petroleum products (Reid method)» provisions measuring gasoline, volatile vapor pressure of the volatile crude oil and other petroleum products. But not for the determination of the vapor pressure of liquefied petroleum gas. Sample at 37.8 ℃ saturated vapor pressure measuring device with Reid formula measured maximum vapor pressure. Reid called the saturated vapor pressure.

RANNSACHAIDH
  • Sònrachadh
  • Buannachd farpaiseach

Tagraidhean:
1. ISO3007, ASTMD323, IP692.
2. Petroleum, cumhachd, ceimigeach, rannsachadh, smachd càileachd agus oilthigh

Sònrachaidhean:

teicnigeach Chrìochan 

Water bath heating power

1600W

Water bath temperature range

Teòthachd an t-seòmair ~ 90

Water bath temperature control accuracy

± 0.1

Gauge accuracy

± 0.4%

Teòthachd àrainneachdail

-10 ~ 35

Àirde na Gaoithe

85%

cumhachd caitheamh

Nas lugha na 1700W

cumhachd

AC220V ± 10%, 50Hz

 

 

 

 

 

 

 

 

feartan 

 

1.Mainly composed of water bath and temperature control devices, bomb vapor pressure gauges and other components. With the use of flexible, mobile, and convenient.

2.Water bath is filled with insulating material laminated cooler, installed in the main bath shop electric heater and electric stirring device, the bath temperature was maintained 37.8 ℃ ± 0.1 , above the bath bomb fitted stent placement test, one can put two only test bombs

3.Temperature control device: temperature control accuracy of 37.8 ± 0.1 , digital display, installed in the electrical box on the left

4.The pressure gauge: the test Reid vapor pressure under different pressures, the instrument is equipped with a variety of standard gauge a set range.

Buannachd farpaiseach

Double-body LCD temperature control, embedded operating system

1. Dèanamh as motha ann an Sìona, solar seata slàn de uidheamachd obair-lann, gabh ri gin  
seòrsa de sgrùdadh factaraidh.
2. Le R & D, Teicneòlas, Riochdachadh, Reic, QC, Às dèidh-reic seirbheis etc  
roinnean, a’ toirt seachad seirbheisean coileanta is proifeasanta.
3. Import accessories bho Bosch, Siemens, Omron, Honeywell, ABB agus mar sin air adhart.
4. Sealbhachadh mòran peutantan neo-eisimeileach agus teisteanasan.
5. Geall prìs reusanta agus bathar as fheàrr.
6. Fòcas air seirbheis às dèidh reic, gheibh ceist sam bith fios air ais taobh a-staigh 24 uairean.
7. Eòlas às-mhalairt beairteach.
8. Dealasach a bhith a' togail suaicheantas ainmeil air feadh an t-saoghail, thoir aire do bheachdan air ais bho gach neach-ceannach.