Automatic closed cup flash point tester is conformed to GB/T261, ASTM D93 and the latest ISO 2719:Determination of flash point -- pensky-martens closed cup method.

RANNSACHAIDH
  • Sònrachadh
  • Buannachd farpaiseach

Place of Origin:

Changsha, Sìona

Brand Ainm:

FRIEND

Modail Àireamh:

FDT-0292

teisteanais:

CE, ISO, CO

Uidheam òrdugh as ìsle:

SET 1

Price:

USD8000-15000

Fiosrachadh Pacaidh:

Cartain cruaidh, pacadh às-mhalairt àbhaisteach

Ùine Lìbhrigeadh: (LEADING)

30 DAYS

Riaghailtean Pàigheadh:

T / T, L / C

Solar Comas:

50 SET / MIS

Tagraidhean:
1. ASTM D93
2. Gasoline, ola lubricant, deuchainn ola connaidh
3. Petroleum, cumhachd, ceimigeach, rannsachadh, smachd càileachd agus oilthigh

Sònrachaidhean:

teicnigeach Chrìochan

cumhachd

AC 220V ± 10%, 50Hz

Raon na

Seòmar teòthachd ~ 300 ℃

Resolution

0.1 ℃

 

Agitation speed

90( r./min)~120(r./min).    (GB/T 261 procedure A,ASTM D93  procedure A)

250(r/min)±10(r/min).   (GB/T261 procedure B,ASTM D93  procedure B)

Astar teasachaidh

5(℃ / min ) ~6(℃ / min )   ( GB/T 261 procedure A,ASTM D93 procedure A)

1(℃ / min )~1.5(℃ / min)( GB/T 261 procedure B,ASTM D93 procedure B )

 

Ignition

Electronic ignition and the gas flame

To adapt to the ambient temperature

10-40 ℃

To adapt to the environment humidity

Caitheamh cumhachd iomlan

Nas lugha na 500W

feart

1. The instrument uses A&B testing process for different types of sample selection. It can also custom set the agitation speed

2. The instrument uses the annular integral heating structure for more uniform heating and more accurate heating rate

3. The Instrument uses the air-cooling temperature control system to ensure the furnace body temperature is constant.

4. The instrument use a self-diagnostic function, instrument failure automatically prompt function

5. The instrument uses a self-over-temperature protection, over-temperature range can be set

6. The instrument uses the LCD touch display, real-time simulation tracking display temperature and test time function curve, the operation interface prompt the real time function

7. The instrument uses the voltage limit technology in Friend’s proprietary intellectual property rights, to ensure the constant of platinum wire heating and improve the instrument testing accuracy

8. The instrument uses the precision machining technology, which is conformed to the structural standard in ASTM D93

9. The instrument uses two kinds of heating devices: electronic ignition and the gas flame, which is convenient and faster.