YX-DL8802 Automatic infrared sulfur analyzer
Instrument standard configuration: 1 computer + 1 printer + 1 set of + YX-DL8802
NCO NTSOOV- specification
- Kev Tshaj Loj (Competitive Advantage)
Scope ntawm daim ntawv thov
Haum rau cov nroj tsuag fais fab, thee mines, tshuaj xyuas khoom, kev tiv thaiv ib puag ncig, kev tshawb nrhiav geological, metallurgy, papermaking, tshuaj lom neeg kev lag luam, kev tshawb fawb, kev kawm thiab lwm lub tuam tsev los txiav txim siab tag nrho cov ntsiab lus ntawm cov tooj liab, coke, roj av thiab lwm yam khoom siv.
Technical parameter
Measuring range: 0.01%~40% (can be expanded according to user requirements)
Test method: infrared spectroscopy absorption method
Sulfur kev daws teeb meem: 0.001%
Working furnace temperature: 1300℃
Kev tswj qhov kub thiab txias: ± 1 ℃
Qauv loj: 300 ± 10mg (coal, coke), 100 ± 10mg (petroleum khoom)
Qauv xa tuaj: tsis siv neeg coj mus kuaj, qauv tso tseg
Tus naj npawb ntawm cov qauv: 12 / batch, cov qauv tuaj yeem ntxiv / hloov pauv thaum kuaj
Lub sij hawm soj ntsuam ib zaug: txog 3 min
Accuracy: In line with GB/T25214-2010 "Determination of Total Sulfur in Coal-Infrared Spectroscopy"
Lub zog: ≤4kW
Ua hauj lwm fais fab mov: AC220V ± 22V / 50Hz
Qhov ntev (hli): 670 × 580 × 720
Loj ntawm tag nrho lub tshuab (kg): 87
Kev Nta
● Automatically complete sample injection, test, discard and output test results, and the sample sending mechanism has won the national patent (utility model patent number: 2013200307699);
● The ultra-low drift infrared cell is used to ensure the stability of the equipment, and the accuracy and accuracy are higher;
● Using the company's unique gas concentration dilution device, the measurement range can be extended without replacing the infrared cell;
● With software fault-tolerant diagnosis function, it can intelligently judge and prompt the fault location;
● Using imported heating elements and combustion tubes, the service life is longer;
● Adopt imported air path components and optimized air path design to ensure the air tightness of the instrument;
● The air inlet pipe and the sample feeding rod are independent, with long service life, convenient maintenance and low cost;
● Nws tuaj yeem txuas nrog lub chaw soj ntsuam kev tswj hwm, kom cov ntaub ntawv sib npaug tsis poob rau hauv av, thiab cov txiaj ntsig kev xeem tau rov qab thiab upload.