cov khoom siv
- General thiab fais fab roj tsom ntsuas ntsuas
- Roj roj, hnyav roj ntsuas ntsuas ntsuas
- Lubricating roj tsom xam ntsuas
- Roj tshuaj ntsuas ntsuas
- Benzene, paraffin, roj, khoom siv
- Antifreeze, asphalt analytical instruments
- Lwm yam cuab yeej analytical
- Roj Chromatograph
- Calorific Value Analysis Series
- Composition Analysis Series
- Elemental Analysis Series
- Physical Property Analysis Series
TIV TAUJ PEB
Ice Bin
Hlau: + 86 15116400852
Mob: + 86 15116400852
E-mail: [email tiv thaiv]
Skype: changshafriend.tester
Whatsapp: + 86 15116400852
YX-DL8810 Tsis siv neeg infrared sulfur analyzer
Instrument standard configuration: 1 computer + 1 printer + 1 set of YX-DL8810
NCO NTSOOV- specification
- Kev Tshaj Loj (Competitive Advantage)
Scope ntawm daim ntawv thov
Haum rau cov nroj tsuag fais fab, thee mines, tshuaj xyuas khoom, kev tiv thaiv ib puag ncig, kev tshawb nrhiav geological, metallurgy, papermaking, tshuaj lom neeg kev lag luam, kev tshawb fawb, kev kawm thiab lwm lub tuam tsev los txiav txim siab tag nrho cov ntsiab lus ntawm cov tooj liab, coke, roj av thiab lwm yam khoom siv.
Technical parameter
Measuring range: 0.01% ~ 40% (can be expanded according to user requirements)
Test method: infrared spectroscopy absorption method
Sulfur kev daws teeb meem: 0.001%
Ua haujlwm kub: 1300 ℃
Kev tswj qhov kub thiab txias: ± 1 ℃
Sample mass: 300±10mg (coal, coke) recommended 200±10mg, 100±10mg (petroleum products)
Qauv xa tuaj: tsis siv neeg coj mus kuaj, qauv tso tseg
Number of samples: 70 samples can be placed at a time, cyclic stakeout, add, delete, and insert test samples at any time
Lub sij hawm soj ntsuam ib zaug: txog 2 min
Precision: in line with GB/T25214-2010 "Determination of Total Sulfur in Coal - Infrared Spectroscopy"
Accuracy: Within the uncertainty range of the standard sample
Power: ≤4KW
Working power supply: AC220V±22V/50Hzq
Qhov ntev (hli): 1240 × 660 × 6
Kev Nta
● Lub MCPC tswj module yog siv los saib xyuas cov xwm txheej ntawm lub cuab yeej hauv lub sijhawm tiag tiag, txuag cov ntsuas qhov ntsuas, thiab ua tiav cov txheej txheem xeem ntawm nws tus kheej yam tsis muaj kev cuam tshuam ntawm lub khoos phis tawj sab saud.
● Using ultra-low drift infrared cell, high precision and accuracy, easier operation;
● 70 samples can be placed at a time, which can be unattended;
● Exhaust gas can be discharged to avoid laboratory air pollution;
● Real-time monitoring of laboratory ambient temperature and humidity;
● The sample feeding system adopts imported servo electric cylinder design, which makes the sample feeding more stable and the failure rate is lower;
● Using three oxygen barrels, the experimental procedures such as air sealing, purging, and combustion are completed respectively, and the test results are accurate;
● Txais cov khoom siv hauv cov huab cua txawv teb chaws thiab txhim kho txoj hauv kev zoo tshaj plaws los xyuas kom muaj huab cua nruj ntawm qhov ntsuas;
● Nws tuaj yeem txuas nrog lub chaw soj ntsuam kev tswj hwm, kom cov ntaub ntawv sib npaug tsis poob rau hauv av, thiab cov txiaj ntsig kev xeem tau rov qab thiab upload.