cov khoom siv
- General thiab fais fab roj tsom ntsuas ntsuas
- Roj roj, hnyav roj ntsuas ntsuas ntsuas
- Lubricating roj tsom xam ntsuas
- Roj tshuaj ntsuas ntsuas
- Benzene, paraffin, roj, khoom siv
- Antifreeze, asphalt analytical instruments
- Lwm yam cuab yeej analytical
- Roj Chromatograph
- Calorific Value Analysis Series
- Composition Analysis Series
- Elemental Analysis Series
- Physical Property Analysis Series
TIV TAUJ PEB
Ice Bin
Hlau: + 86 15116400852
Mob: + 86 15116400852
E-mail: [email tiv thaiv]
Skype: changshafriend.tester
Whatsapp: + 86 15116400852
ASTM D381 FDR-0502 Roj Hmab Cov Ntsiab Lus Tester (Jet Evaporation)
Requirements The instrument is designed for the determination of aviation gasoline and motor gasoline gum content of the instrument, applicable to ASTM D381, GB / T 8019 "motor gasoline and aviation fuel gum assay (Jet evaporation method)" set forth in on aviation gasoline and gasoline vehicles tested in gum content requirements.
NCO NTSOOV- specification
- Kev Tshaj Loj (Competitive Advantage)
Daim ntaub ntawv:
1. ASTM D381, GB / T 8019
2. Motor gasoline and aviation fuel
3. Petroleum, lub zog, tshuaj lom neeg, kev tshawb fawb, kev tswj xyuas zoo thiab tsev kawm ntawv qib siab
Specifications:
Kev Tsis | |
Fais fab mov | 220V ± 10%, 50Hz, 2.5kW |
Cov txheej txheem cua sov | Heating the metal bath |
Test holes | 3 los yog 5 |
Ua haujlwm kub | 160 ~ 165 ℃ |
Kev ntsuas kub tswj txoj kev | Tsis siv neeg tswj qhov kub thiab txias |
Kub zaub | LCD zaub |
Flow display | Meter zaub |
Roj qhov chaw | External air,> 1000 ± 150mL / sec |
| |
nta
| 1.The instrument uses metal bath heating system, heating speed, temperature uniformity bath body |
| 2. The instrument configuration regulator system, the experiment intake stable, safe |
| 3. Instrument configuration independent of the gas supply system, can be adjusted independently of each test hole hot air flow, hot air flow control is accurate and reliable |
| 4. Instrument imported (Omron) temperature control, LCD display, high precision temperature control, low failure rate |
| 5.The instrument uses a protective circuit to avoid voltage or current increases damage to equipment and operating personnel |
Hu Rau Peb
Lwm Yam Khoom
-
ASTM D5453 FDR-3301 Petroleum khoom sulfur ntsiab lus tester (UV fluorescence method)
-
> ASTM D664 FDR-2272 Tsis siv neeg cov kua qaub ntawm cov khoom siv roj av
-
> ASTM D4530 FDR-1901 Tsis Siv Neeg Carbon residue tester (Micro Method)
-
ASTM D2274 FDR-0403 Distillate roj roj oxidation stability tester (txoj kev acceleration)
-
> ASTM D323 FDR-0271 Tsis Siv Neeg saturated vapor siab tester (Reid method)
-