astm_d93_fdt_0201_open_cup_flash_point_and_fire_point_tester
ASTM D93 FDT-0201, Qhib khob qhov taw qhia thiab hluav taws kub ntsuas ntsuas

ASTM D93 FDT-0201, Qhib khob qhov taw qhia thiab hluav taws kub ntsuas ntsuas

The instrument is designed and manufactured in accordance with ASTM D93 standard.

NCO NTSOOV
  • specification
  • Kev Tshaj Loj (Competitive Advantage)

Qhov chaw ntawm keeb kwm:

Changsha, Suav teb

Hom Npe:

phooj ywg

Model Number:

TSW-0201

Certification:

CE, ISO, CO

 

Yam Tsawg Tshaj:

1 SET

Nqe:

USD600-2000

Ntim Paub meej:

Hard carton, Standard export packing

Lub sij hawm xa tuaj: (LEADING)

30 HNUB

Ntsiab lus uas them:

T / T, L / C

Mov Muaj peev xwm:

50SET/HMO

Daim ntaub ntawv:
1. ASTM D93 XNUMX
2. Roj av, roj nplua nyeem, roj av kuaj
3. Petroleum, lub zog, tshuaj lom neeg, kev tshawb fawb, kev tswj xyuas zoo thiab tsev kawm ntawv qib siab

Specifications:

Kev Tsis

Fais fab mov

AC 220V ± 10%, 50Hz

Lub tshuab cua sov

Heating power from 0 ~ 600W continuously adjustable

Sample heating rate

1 ~ 12 ℃ / min, it can be controlled.

Electric mixing device

(1) 90 ~ 120 r / min for the test step A.

(2) 250 ± 10 rev / min for the test step B.

 

 

Electric mixing device

(1) 90 ~ 120 r / min for the test step A.

(2) 250 ± 10 rev / min for the test step B.

 

Standard oil cup

(1) Diameter: 50.7 ~ 50.8 mm.

(2) Depth: 55.7 ~ 56.0 mm.

(3) Test oil capacity groove depth: 33.9 ~ 34.3 mm.

(4) Test oil capacity: about 70 ml.

 

Tus pas ntsuas kub

A bar mercury thermometer, in line with GB / T 261-2008 standards.

(1) temperature range -5 ~ 110 ℃, indexing 0.5 ℃.

(2) temperature range of 20 ~ 150 ℃, indexing 1.0 ℃.

(3) temperature range of 90 ~ 370 ℃, dividing 2 ℃.

 

ignition

(1) ignition sources: gas (or other civilian combustible gas, the same below). (2) pilot aperture: 0.8 mm.

Qhov kub thiab txias:

≤35 ℃.

txheebze vaum

≤85%.

Kev siv fais fab tag nrho

Tsawg dua 650W.

feature

1. the instrument is designed in full compliance with ASTM D93, GB/T261 standards.

2. heating power continuously, stepless adjustable, voltmeter intuitive display power size, advanced, reasonable temperature control.

3. compact structure, stainless steel countertops, easy to clean oil.

4. easy to operate, the test results are accurate, the instrument was a number of measurement units selected as closed flash point detection equipment.