Tel: + 86 15116400852
EN
Txhua pawg

Tsev> cov khoom siv > General thiab fais fab roj tsom ntsuas ntsuas

TIV TAUJ PEB

Ice Bin

Hlau: + 86 15116400852

Mob: + 86 15116400852

E-mail: [email tiv thaiv]

Skype: changshafriend.tester

Whatsapp: + 86 15116400852

TSIS TAU
TSIS TAU
TSIS TAU
FDT-0293 Automatic Optiflash Abel Flash Point Tester
FDT-0293 Automatic Optiflash Abel Flash Point Tester
FDT-0293 Automatic Optiflash Abel Flash Point Tester

FDT-0293 Automatic Optiflash Abel Flash Point Tester

The Apparatus is designed and manufactured in accordance with the requirements of the GB/T21789, IP 170,ISO13736 "Petroleum products and other liquids-Determination of flash point-Abel closed cup method", which can meet petroleum, chemical, paint, railway, aviation, The requirements for rapid testing of closed flashpoints of petroleum products by electricity, commodity inspection, military and scientific research units.

NCO NTSOOV
  • specification
  • Kev Tshaj Loj (Competitive Advantage)

Qhov chaw ntawm keeb kwm:

Changsha, Suav teb

Hom Npe:

Cov phooj ywg

Model Number:

TSW-0293

Certification:

ISO, CE, CO

MOQ:
1 SET

Nqe:

20000-30000 $
Ntim Detail:Hard Carton, Export Standard
Tus me nyuam lub sij hawm:
30 Hnub
Ntsiab lus uas them:
T/T; L/C
Mov Muaj peev xwm:
50Sets/month

daim ntawv thov: 

1.GB/T 21789  ISO 13736  GB/T 27847

2. Diesel, Lubricant Oil

3. Petroleum, Power, Chemical, Research Institution, Quality Control, And University

specification:

Ua haujlwm fais fab:AC 220V ± 10%, 50Hz
Ntau yam:30 ~ 70℃;
daws teeb meem:0.1 ℃
Hom txias:compressor refrigeration, automatic cycle
Ignition mode:electric/gas ignition
Qhov kub thiab txias:10-45 ℃
Ib puag ncig cov av noo
Fais fab kev noj:500W



Kev Tshaj Loj:

1.This instrument can perform experiments on different types of samples and standards, and it can also customize the sample stirring speed

2.The heating of the instrument is more uniform and the heating rate is more accurate

This instrument ensures that the ambient temperature of the furnace body is consistent

3.The instrument will automatically prompt when there is a failure, and the over-temperature range can be set at will

4.The instrument comes with real-time simulation and tracking to display the function curve of heating and test time

5.This instrument ensures that the platinum wire heats up to the same amount of heat and improves the accuracy of the instrument

6.This instrument can be set according to different sample standard requirements



Hu Rau Peb