pwodwi yo
- Enstriman analiz jeneral ak pouvwa lwil oliv
- Lwil gaz, sòlvan enstriman analiz lwil oliv
- Enstriman analiz lwil oliv lubrifyan
- Enstriman analiz grès
- Benzèn, parafin, gaz, ekipman
- Antijèl, asfalt enstriman analyse
- Lòt enstriman analyse
- Chromatograph gaz
- Seri analiz valè kalorifik
- Seri analiz konpozisyon
- Seri analiz elemantè
- Seri analiz pwopriyete fizik
KONTAKTE NOU
Ice Bin
Tel: + 86 15116400852
Foul: + 86 15116400852
E-mail: [imèl pwoteje]
Skype: changshafriend.tester
Whatsapp: + 86 15116400852
YX-ZR9706 Otomatik kalorimètr
Instrument standard configuration: 1 computer + 1 printer + 1 set of YX-ZR9706
- Spesifikasyon
- konpetitif Advantage
Dimansyon de aplikasyon
It is widely used in power plants, coal mines, commodity inspection, environmental protection, geological exploration, metallurgy, papermaking, chemical industry, scientific research, education and other departments to determine the calorific value of coal, coke, petroleum, solid waste and cement black raw meal and other combustible substances.
Teknik paramèt
Temperature measurement range: 5℃~40℃
Precision: ≤0.1%
Heat capacity stability: change in heat capacity within one year ≤ 0.2%
Accuracy: better than GB/T213-2008 "Method for Determination of Calorific Value of Coal"
Temperature Resolution: 0.0001℃
Single sample test time: ≤13min (classical method), ≤10min (quick method)
Travay ekipman pou pouvwa: AC220V±22V/50Hz
Power: ≤0.8 kW
Main box size (mm): 520×520×500
Side box size (mm): 460×470×500
Mas tout machin lan (kg): 115
Karakteristik teknik
● Five probes are used for real-time temperature sensing. During the test, the outer cylinder, inner cylinder, temperature-adjusting water tank, constant temperature water tank and room temperature are respectively detected in real time, so as to truly realize the automatic adjustment of the temperature of the inner and outer cylinders;
● The MCPC control module is used to monitor the status of the instrument in real time, save the parameters of the instrument, and complete the test process independently without the intervention of the upper computer.
● Adopting a new type of automatic oxygen filling and degassing device and an automatic lifting mechanism of the oxygen bomb, the oxygen bomb is automatically raised and lowered, and the oxygen is charged and discharged automatically, with a high degree of automation and simple and convenient operation;
● Using the automatic identification technology of oxygen bombs, it can automatically distinguish the heat capacity of different oxygen bombs (utility model patent numbers: 2013200307701, 201320036818X);
● The pump circulation method is adopted, so that the temperature of each point of the whole calorimetric system of the instrument is quite balanced to ensure the accuracy of the test results;
● Adopt thermal insulation material to isolate the influence of external environment, and the instrument has strong anti-interference ability;
● The probe-type electronic measuring cup is used to automatically measure the water volume in the inner cylinder. The repetition error is less than 0.5g, and the water volume in the inner cylinder is accurate and stable. Short test time and accurate results;
● The automatic identification function of the ignition wire can accurately judge the bad state of the ignition wire;
● Adopt digital barometer for easy observation;
● The test water filter device is used to prevent impurities from clogging the waterway;
● According to the working conditions of the laboratory, it can be converted from a desktop to a vertical structure;
● Li ka konekte ak sistèm jesyon laboratwa a, pou done balans yo pa tonbe atè, epi rezilta tès yo apiye ak Uploaded;
● Special oxygen bombs, crucibles and other accessories can be selected for solid waste samples;
● Optional oxygen bomb gas collection device for gas collection in the oxygen bomb.