pwodwi yo
- Enstriman analiz jeneral ak pouvwa lwil oliv
- Lwil gaz, sòlvan enstriman analiz lwil oliv
- Enstriman analiz lwil oliv lubrifyan
- Enstriman analiz grès
- Benzèn, parafin, gaz, ekipman
- Antijèl, asfalt enstriman analyse
- Lòt enstriman analyse
- Chromatograph gaz
- Seri analiz valè kalorifik
- Seri analiz konpozisyon
- Seri analiz elemantè
- Seri analiz pwopriyete fizik
KONTAKTE NOU
Ice Bin
Tel: + 86 15116400852
Foul: + 86 15116400852
E-mail: [imèl pwoteje]
Skype: changshafriend.tester
Whatsapp: + 86 15116400852
YX-DL8802 Automatic infrared sulfur analyzer
Instrument standard configuration: 1 computer + 1 printer + 1 set of + YX-DL8802
INQUIRY- Spesifikasyon
- konpetitif Advantage
Dimansyon de aplikasyon
Suitable for power plants, coal mines, commodity inspection, environmental protection, geological exploration, metallurgy, papermaking, chemical industry, scientific research, education and other departments to determine the total sulfur content of coal, coke, petroleum and other substances.
Teknik paramèt
Measuring range: 0.01%~40% (can be expanded according to user requirements)
Test method: infrared spectroscopy absorption method
Rezolisyon mezi souf: 0.001%
Working furnace temperature: 1300℃
Presizyon kontwòl tanperati: ± 1 ℃
Egzanp mas: 300±10mg (chabon, coke), 100±10mg (pwodwi petwòl)
Metòd livrezon echantiyon: livrezon echantiyon otomatik, abandon echantiyon
Kantite echantiyon: 12/pakèt, echantiyon yo ka ajoute/ranplase pandan tès la
Tan analiz echantiyon sèl: apeprè 3min
Accuracy: In line with GB/T25214-2010 "Determination of Total Sulfur in Coal-Infrared Spectroscopy"
Pouvwa: ≤4kW
Travay ekipman pou pouvwa: AC220V±22V/50Hz
Dimansyon (mm): 670×580×720
Mas tout machin lan (kg): 87
Karakteristik teknik
● Automatically complete sample injection, test, discard and output test results, and the sample sending mechanism has won the national patent (utility model patent number: 2013200307699);
● The ultra-low drift infrared cell is used to ensure the stability of the equipment, and the accuracy and accuracy are higher;
● Using the company's unique gas concentration dilution device, the measurement range can be extended without replacing the infrared cell;
● With software fault-tolerant diagnosis function, it can intelligently judge and prompt the fault location;
● Using imported heating elements and combustion tubes, the service life is longer;
● Adopt imported air path components and optimized air path design to ensure the air tightness of the instrument;
● The air inlet pipe and the sample feeding rod are independent, with long service life, convenient maintenance and low cost;
● Li ka konekte ak sistèm jesyon laboratwa a, pou done balans lan pa tonbe sou tè a, epi rezilta tès yo apiye ak Uploaded.