ngwaahịa
KPỌTỤRỤ ANYỊ
Ice Bin
Tel: 86-0731-83889629
Mob: 86 13548954520
E-mail: [email protected]
Skype: changshafriend.nnwale
Whatsapp: 86 13548954520
GB/T 384,FDR-4251 Ngwa mmanụ ala akpaaka calorific value tester
Automatic petroleum products calorific value meter in line with GB / T384, for electric power, coal, paper, petrochemical, cement, agriculture and animal husbandry, medical research, teaching and other industries and sectors measuring the calorific value of coal, oil and other combustibles.
NCHỌPỤTA- nkọwapụta
- asọmpi Advantage
ngwa:
1. GB / T384
2. Ngwaahịa mmanụ ala
3. Petroleum, ike, kemịkalụ, nyocha, njikwa mma na mahadum
nkọwa:
Nka na ụzụ kwa | |
Okpomọkụ nso: | 5 ℃ ~ 40 ℃ |
Mkpebi okpomọkụ: | 0.0001 ℃ |
Heat capacity precision: | ≤0.1% |
Test of time: | The main stage around 8min |
Nchọpụta: | Nchọpụta akpaaka |
Control: | Njikwa Kọmputa |
| |
atụmatụ | 1. The instrument configuration ampoule capsule exclusive national standards were tested on biodiesel and other light detecting volatile oil, the accuracy is greatly improved. It is an alternative of traditional Calorimeter of volatile oil sample test results excessive deviation device of choice. (Customer when ordering, please indicate the test sample) |
2. The high degree of automation: automatic temperature control, automatic and accurate quantification of water within the cylinder, automatic cycle inner tube water level automatically determine the outer cylinder, manual operation only for said sample weight, loaded aerobic bombs, other fully automatic control performed by the instrument ,Convenient. | |
3. High precision: using accurate temperature measurement system, temperature resolution of up to 0.0001 ℃, to achieve accurate measurements.
| |
| 4. The test results are stable and reliable: the standard correction formula, the result is true and reliable.
|
| 5. Powerful software: a self-diagnostic function, with clear operating and status prompts, can be a variety of data processing calorific needs.
|
| 6. Oxygen bomb structure: Friends specially dedicated oxygen bomb, can be pre-ignition wire is bad, resulting in the phenomenon of the test can not be normal. Improve work efficiency.
|
| 7. Using new compact automatic oxygen bomb oxygenation device, without manual pressure
|
| 8. Reserved standard interfaces: Electronic scales can sample weight automatically entered; can be easily coupled to a local area network. Asynchronous multi-control technology, a computer controlled multiple automatic cylinder or our other instruments |
Kpọtụrụ Anyị
njikọ Product
-
ASTM D2700, ASTM D2699 FDR-3562 Octane tester (moto / usoro nyocha)
-
-
-
> ASTM D4530 FDR-1901 Ihe nleba anya carbon na-akpaghị aka (Usoro Micro)
-
> ASTM D86 FDR-0843 Distillation nke ihe nlere ngwaahịa mmanụ ala (obere tem. Ọkpụkpọ abụọ)
-
ASTM D381 FDR-0502 Ihe nleba anya ọdịnaya chịngọm (Jet evaporation)