פרמטר טכני
Temperature control range: RT+10~1000℃
דיוק בקרת טמפרטורה: ± 2 ℃
Sample mass: 0.5~1.2g, recommended: 1±0.1g
Number of samples: 20/batch
Test time: 180min/20 samples (classical method), 100 min/20 samples (quick method)
Working power supply: AC 220V±22V/50Hz
Power: ≤6kW
7706A Dimensions (mm): 630×560×580 Weight (kg): 90
7706B Dimensions (mm): 560×560×750 Weight (kg): 80

מאפיינים טכניים
● Adopt MCPC control module and balance display module to monitor the status of the instrument in real time, save the instrument parameters, complete the test process independently, without the intervention of the host computer, realize offline operation, and self-diagnosis reminder of the instrument, which greatly improves the reliability of the instrument;
● Using stepper motor and high-precision angle encoder control system (utility model patent number: 2017205786217), accurate positioning and fast sample weighing;
● With the power-off memory function, the test data will not be lost if the test process is interrupted unexpectedly, and the test can be automatically completed when the power is turned on;
● The use of distributed intelligent smoke exhaust interface can more effectively exhaust smoke and dust, and is more environmentally friendly;
● Using PID temperature control algorithm, the temperature control accuracy is higher;
● The test process, conditions and results of moisture, ash and volatile matter meet the requirements of the national standard, and the results of moisture and ash content are better than the requirements of the national standard, and do not need to be corrected;
● It adopts multi-furnace and double balance structure, which can be measured in any combination or individually, and does not require an external gas source;
● Adopt automatic flip device to avoid high temperature radiation and burns of operators;
● Using thermogravimetric analysis method, automatic sample weighing, automatic sample delivery, automatic data processing, result calculation, report printing and storage, etc., to achieve unattended;
● The heat insulation device is added at the bottom of the high temperature furnace to reduce heat radiation and ensure that the coal sample is not oxidized, and the temperature control of the constant temperature room is more accurate;
● It can be connected to the laboratory management system, so that the balance data does not fall on the ground, and the test results are backed up and uploaded.