Produkter
- Allgemeng a Kraaft Ueleg Analyse Instrument
- Brennstoff Ueleg, Léisungsmëttelbad Ueleg Analyse Instrument
- Schmierölanalyseinstrument
- Fett Analyse Instrument
- Benzen, Paraffin, Gas, Ausrüstung
- Antifreeze, Asphalt analytesch Instrumenter
- Aner analytesch Instrumenter
- Gas Chromatograph
- Kaloresch Wäert Analyse Serie
- Zesummesetzung Analyse Serie
- Elemental Analyse Serie
- Kierperlech Property Analyse Serie
KONTAKTÉIERT EIS
Äisdreckskëscht
Telefon: + 86 15116400852
Mob: + 86 15116400852
E-mail: [Email geschützt]
Skype: changshafriend.tester
Whatsapp: + 86 15116400852
YX-DL8802 Automatesch Infrarout Schwefel Analyser
Instrument standard configuration: 1 computer + 1 printer + 1 set of + YX-DL8802
Ëmfro- bestëmmen
- Kompetitiv Virdeel
Ëmfang vun der Applikatioun
Gëeegent fir Kraaftwierker, Kuelegrouwen, Commodity Inspektioun, Ëmweltschutz, geologesch Exploratioun, Metallurgie, Papermaking, chemesch Industrie, wëssenschaftlech Fuerschung, Educatioun an aner Departementer fir de Gesamt Schwefelgehalt vu Kuel, Kock, Petrol an aner Substanzen ze bestëmmen.
Technesche Parameter
Measuring range: 0.01%~40% (can be expanded according to user requirements)
Testmethod: Infraroutspektroskopie Absorptiounsmethod
Schwefelmiessungsopléisung: 0.001%
Aarbechtsofentemperatur: 1300 ℃
Temperatur Kontroll Genauegkeet: ± 1 ℃
Probemass: 300±10mg (Kuel, Koks), 100±10mg (Petroleumprodukter)
Echantillon Liwwerung Method: automatesch Echantillon Liwwerung, Prouf opginn
Unzuel vun Echantillon: 12/Batch, Echantillon kënne während dem Test dobäi ginn / ersat ginn
Single Probe Analyse Zäit: ongeféier 3min
Accuracy: In line with GB/T25214-2010 "Determination of Total Sulfur in Coal-Infrared Spectroscopy"
Leeschtung: ≤4 kW
Aarbecht Muecht Fourniture: AC220V ± 22V / 50Hz
Dimensiounen (mm): 670 × 580 × 720
Mass vun der ganzer Maschinn (kg): 87
Technesch Features
● Automatically complete sample injection, test, discard and output test results, and the sample sending mechanism has won the national patent (utility model patent number: 2013200307699);
● The ultra-low drift infrared cell is used to ensure the stability of the equipment, and the accuracy and accuracy are higher;
● Using the company's unique gas concentration dilution device, the measurement range can be extended without replacing the infrared cell;
● With software fault-tolerant diagnosis function, it can intelligently judge and prompt the fault location;
● Using imported heating elements and combustion tubes, the service life is longer;
● Adoptéiert importéiert Loftweekomponenten an optiméiert Loftwee Design fir d'Loftdichtheet vum Instrument ze garantéieren;
● The air inlet pipe and the sample feeding rod are independent, with long service life, convenient maintenance and low cost;
● Et kann mat dem Laboratoire Management System verbonne sinn, sou datt d'Balancedaten net op de Buedem falen, an d'Testresultater ginn gebacken an eropgelueden.