Tel: + 86 15116400852
EN
Categories onse

Kunyumba> Zamgululi > Elemental Analysis Series

LUMIKIZANANI NAFE

Ice Bin

Nambala: + 86 15116400852

Mob: + 86 15116400852

E-mail: [imelo ndiotetezedwa]

Skype: changshafriend.tester

WhatsApp: + 86 15116400852

3-3
YX-DL8810 Automatic infrared sulfure analyzer

YX-DL8810 Automatic infrared sulfure analyzer

Instrument standard configuration: 1 computer + 1 printer + 1 set of  YX-DL8810

Kufufuza
  • mfundo
  • Mpikisano Wopikisana

Chiwerengero cha ntchito
Oyenera zomera mphamvu, migodi malasha, katundu anayendera, kuteteza chilengedwe, kufufuza nthaka, zitsulo, papermaking, makampani mankhwala, kafukufuku wa sayansi, maphunziro ndi madipatimenti ena kudziwa okwana sulfure zili malasha, coke, mafuta ndi zinthu zina.

Zida zamakono
Measuring range: 0.01% ~ 40% (can be expanded according to user requirements)
Njira yoyesera: njira yoyamwitsa ya infrared spectroscopy
Sulfure muyeso wa kuyeza: 0.001%
Kutentha kwa ng'anjo yogwira ntchito: 1300 ℃
Kulondola kwazowonjezera kutentha: ± 1 ℃
Sample mass: 300±10mg (coal, coke) recommended 200±10mg, 100±10mg (petroleum products)
Njira yoperekera zitsanzo: kutumiza zitsanzo zokha, kusiya zitsanzo
Number of samples: 70 samples can be placed at a time, cyclic stakeout, add, delete, and insert test samples at any time
Nthawi yowunika yachitsanzo chimodzi: pafupifupi 2min
Precision: in line with GB/T25214-2010 "Determination of Total Sulfur in Coal - Infrared Spectroscopy"
Accuracy: Within the uncertainty range of the standard sample
Power: ≤4KW
Working power supply: AC220V±22V/50Hzq
Makulidwe (mm): 1240 × 660 × 6

Makhalidwe Abwino
● Gawo lowongolera la MCPC limagwiritsidwa ntchito kuyang'anira momwe chipangizocho chilili mu nthawi yeniyeni, kusunga magawo a chidacho, ndikumaliza kuyesa mosayembekezeka popanda kulowererapo kwa makompyuta apamwamba.
● Using ultra-low drift infrared cell, high precision and accuracy, easier operation;
● 70 samples can be placed at a time, which can be unattended;
● Exhaust gas can be discharged to avoid laboratory air pollution;
● Real-time monitoring of laboratory ambient temperature and humidity;
● The sample feeding system adopts imported servo electric cylinder design, which makes the sample feeding more stable and the failure rate is lower;
● Using three oxygen barrels, the experimental procedures such as air sealing, purging, and combustion are completed respectively, and the test results are accurate;
● Landirani zigawo za njira za mpweya zomwe zimatumizidwa kunja ndi kukonzedwa bwino kwa njira ya mpweya kuti zitsimikizire kulimba kwa mpweya wa chipangizocho;
● Ikhoza kugwirizanitsidwa ndi kayendetsedwe ka kayendetsedwe ka ma laboratory, kuti deta yolondola isagwere pansi, ndipo zotsatira za mayeso zimasungidwa ndikuyikidwa.

123jpg3-14567

Lumikizanani nafe