Tel: + 86 15116400852
EN
Categories onse

Kunyumba> Zamgululi > Mafuta amafuta, chida chowunikira mafuta osungunulira

LUMIKIZANANI NAFE

Ice Bin

Nambala: + 86 15116400852

Mob: + 86 15116400852

E-mail: [imelo ndiotetezedwa]

Skype: changshafriend.tester

WhatsApp: + 86 15116400852

astm_d86_fdr_0843__distillation_of_petroleum_products_tester_low_tem_two_pipe
ASTM D86 FDR-0843 Distillation of petroleum products tester (low tem. Two pipe)

ASTM D86 FDR-0843 Distillation of petroleum products tester (low tem. Two pipe)

Applicable to the standard GB / T6536 «Petroleum products - Determination of distillation» regulations and international standards ISO3405, American standard ASTMD86 / 72, British Standard Test Method IP123 / 78 regulations, natural gasoline (stable light hydrocarbon), motor gasoline, aviation gasoline, jet fuel, special boiling point solvent, naphtha, petroleum solvent oil, kerosene, diesel fuel, gas oil, distillate fuels and similar petroleum products Determination of distillation.

Kufufuza
  • mfundo
  • Mpikisano Wopikisana

Mapulogalamu:
1. GB / T6536, ASTMD86
2. Mafuta amafuta
3. Mafuta, mphamvu, mankhwala, kafukufuku, kulamulira khalidwe ndi yunivesite

zofunika:

luso magawo 

mphamvu chakudya

220V ± 10%, 50Hz

Mphamvu yamagetsi yamagetsi

1000W × 2

Voliyumu ya silinda

100 ml, 1 ml divisions

Botolo la distillation

125mL

Ozizira kusamba kutentha osiyanasiyana

0-60 °

Kutentha kwa nthunzi

 Room temperature -400

 

 

 

 

 

 

 

 

Mawonekedwe 

 

1.The instrument is low, double-pipe work, set at low temperatures, can be single-tube independent testing, also can be tested on two samples of the same size or different sizes at the same time, greatly improving the work efficiency .

2.Using two independent digital temperature controller, heater, cooler, electric mixer to form two thermostatic bath, two-bath temperatures were independently adjustable controllable, uniform temperature within the bath, fully meet the test requirements.

3. Using a special form of furnace, ensure the safety of the test; the heating power continuously adjustable to meet the requirements of the test.

  

Mpikisano Wopikisana

Imported compressor refrigeration Cold bath temperature range: 0~60°C, detection range: room temperature-400°, double tube detection, liquid crystal display, embedded operating system

1. Chopanga chachikulu kwambiri ku China, perekani zida zonse za labu, vomerezani chilichonse  
mitundu ya kafukufuku wamafakitale.
2. Ndi R&D, Technology, Production, Sales, QC, After-sale service etc  
m'madipatimenti, amapereka chithandizo chokwanira komanso chaukadaulo.
3. Tengani zipangizo kuchokera ku Bosch, Simens, Omron, Honeywell, ABB ndi zina zotero.
4. Kukhala ndi ma patent ambiri odziyimira pawokha ndi ziphaso.
5. Lonjezani mtengo wololera ndi zinthu zabwino kwambiri.
6. Yang'anani kwambiri pa ntchito yogulitsa pambuyo pogulitsa, funso lililonse lidzalandira mayankho mkati mwa maola 24.
7. Kulemera kwa katundu wogulitsa kunja.
8. Wodzipereka kupanga mtundu wodziwika bwino padziko lonse lapansi, tcherani khutu ku mayankho ochokera kwa kasitomala aliyense.

1 2 3jpg 3-14 5 6 7

Lumikizanani nafe