YX-WK7302 Otometi muffle ogaumu
It is used in power plants, coal mines, commodity inspection,
environmental protection, chemical industry, scientific research,
education and other departments to determine the ash and volatile
content of coal, coke, petroleum and other substances.
- Specification
- Faʻamanuiaga Faʻamasino
Aotelega o le talosaga
E faʻaaogaina i fale eletise, koale, suʻesuʻega o oloa, puipuiga o le siosiomaga, alamanuia vailaʻau, suʻesuʻega faasaienisi, aʻoaʻoga ma isi matagaluega e fuafua ai le lefulefu ma mea faʻafefe o le koale, coke, petroleum ma isi mea.
Taʻiala faʻapitoa
Va'aiga o le vevela: RT+10~1000℃
Fuafuaga fua o le vevela: 1℃
Vevela pulea sao: ± 3 ℃
Setting time: ≤5999min
Galuega fa'ata'ita'i: fa'agesegese lemu, efuefu vave, fa'aletonu ma isi polokalame masani
Numera o fa'ata'ita'iga: 12 fasi/taimi mo le efuefu, 6 fasi/taimi mo mea fe'avea'i
Furnace door movement parameters: linear movement 250mm
Malosiaga galue: AC 220V±22V/50Hz
Malosiaga: ≤4kW
Host size (mm): 590×51
Tulaga Faʻatino
● Manual and self-integrated human-friendly design, which can automatically or manually send and output samples;
● Put the sample on the sample holder and press the corresponding key to start the test. The sample will not deflagrate during the test, which increases the success rate of the experiment and reduces the labor intensity, especially suitable for fast ash experiments. When doing the fast ash test, the sample is automatically sent in strict accordance with the requirements of the national standard, and there is no need to manually push the sample holder in front of the high temperature furnace;
● Faʻaaogaina o le PID temperature control algorithm, o le saʻo o le vevela e maualuga atu;
● Saʻo le vevela ma le taimi e pulea, o le filifiliga suʻega suʻega e mafai ona faafaigofieina le tagata faʻaoga e faia le suʻega afi, poʻo le pulea o le vevela ma le taimi e tusa ai ma le manaʻoga o le tagata faʻaoga;
● Faʻaaogaina polycrystalline mullite fiber ogaumu, o le eria tumau vevela e lautele, o le vevela e mautu, o le vevela ma le cooling saoasaoa e vave, e mafai ona siitia i le 920 ℃ i le 15 minute, ma le suʻega e mafai ona toe faia i le tele o taimi i le aso;
● The control board adopts a new temperature conversion chip calibrated by laser etching, with functions such as cold junction compensation, burnout protection and over-temperature software protection;
● E mafai ona faʻafesoʻotaʻi i le faiga o le pulega falesuesue e iloa ai le faʻamaumauga ma le tuʻuina atu o suʻega suʻega.