ASTM D381 FDR-0502 Fuels Gum Content tester (Jet Evaporation)
Requirements The instrument is designed for the determination of aviation gasoline and motor gasoline gum content of the instrument, applicable to ASTM D381, GB / T 8019 "motor gasoline and aviation fuel gum assay (Jet evaporation method)" set forth in on aviation gasoline and gasoline vehicles tested in gum content requirements.
fesili- Specification
- Faʻamanuiaga Faʻamasino
talosaga:
1. ASTM D381, GB / T 8019
2. Motor gasoline and aviation fuel
3. Suauʻu, malosi, vailaʻau, suʻesuʻega, pulea lelei ma iunivesite
auiliili:
le faataamilosaga Technical | |
tuuina atu le mana | 220V ± 10%, 50Hz, 2.5kW |
Le auala vevela | Heating the metal bath |
Pu su'ega | 3 po 5 |
Le vevela galue | 160 ~ 165 ℃ |
Vevela pulea metotia | Otometi pulea vevela |
Faʻaaliga o le vevela | Faʻaaliga LCD |
Flow display | Fa'aaliga mita |
Kasa punavai | External air,> 1000 ± 150mL / sec |
| |
Features
| 1.The instrument uses metal bath heating system, heating speed, temperature uniformity bath body |
| 2. The instrument configuration regulator system, the experiment intake stable, safe |
| 3. Instrument configuration independent of the gas supply system, can be adjusted independently of each test hole hot air flow, hot air flow control is accurate and reliable |
| 4. Instrument imported (Omron) temperature control, LCD display, high precision temperature control, low failure rate |
| 5.The instrument uses a protective circuit to avoid voltage or current increases damage to equipment and operating personnel |