ASTM D6079, FDR-5471 Diesel lubricity tester(HFRR)
Complies with SH/T0765-2005 "Diesel Lubricity Assessment Method (High Frequency Reciprocating Tester Method)", ASTM D6079 "Test Method for Evaluating Diesel Lubricity with High Frequency Reciprocating Test Bench (HFRR)" (ISO12156-1:1997, MOD standard method) required technical indicators.
INQUIRY- detalye
- Competitive Advantage
Mga Application:
1. ASTM D6079,SH/T0765
2. Diesel
3. Petroleum, kapangyarihan, kemikal, pananaliksik, kontrol sa kalidad at unibersidad
Mga pagtutukoy:
Teknikal Mga Parameter | |
Maximum rated displacement (stroke) of the vibration exciter | ±3mm; accuracy 0.001mm
|
Experimental temperature | Room temperature -200 ° C, any adjustment |
Katumpakan ng kontrol sa temperatura | ± 0.1 ° C |
Saklaw ng puwersa ng pagsubok | 0-1Kg, friction measurement range: 0-45N |
Parangal: | 100 times; accuracy: 1 micron; |
Constant temperature and humidity box:
| Temperature control range: 17~28°C, temperature display accuracy 0.1°C, temperature control accuracy ±2°C |
Control humidity range:
| 25-70%, humidity display accuracy 1%, humidity control accuracy ≤ 3% RH; |
Kapaligiran ng pagpapatakbo:
| Temperature 5 to 35 ° C, humidity: 20-80% |
Working power: , | AC220V, 50HZ |
The whole machine power: | 2000W |
Reciprocating displacement | mm 1.0 ± 0.02 |
Reciprocating frequency /Hz | 50 1 ± |
Application load / g | 200 1 ± |
Oil sample volume / ml | 2 0.2 ± |
Oil sample temperature / °C | 60 2 ± |
Test time / min | 75 0.1 ± |
| |
Mga tampok | 1. Wear scar measurement system: electronic imaging system, can collect and store images; x, y two directions of reading; magnification: 100 times; accuracy: 1 micron
|
Makipag-ugnayan sa amin
Mga kaugnay na produkto
-
>GB/T 384,FDR-4251 Awtomatikong produktong petrolyo calorific value tester
-
-
-
>ASTM D130 FDR-1141 Mga produktong petrolyo na tanso na tester ng kaagnasan
-
>ASTM D2274 FDR-0403 Distillate fuel oil oxidation stability tester (paraan ng acceleration)
-
>ASTM D323 FDR-0271 Awtomatikong saturated vapor pressure tester (Reid method)